Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 349
Filter
1.
Braz. dent. sci ; 27(1): 1-11, 2024. tab
Article in English | LILACS, BBO | ID: biblio-1537767

ABSTRACT

Objective: This systematic review aims to compare the clinical longevity of metallic and fiberglass intraradicular posts in teeth with severely compromised crowns, utilizing randomized clinical trials and case reports published in the last eleven years. Material and Methods: The research was conducted on PubMed, Medline, Lilacs, and BBO databases using the first search strategy with the descriptors 'dental posts,' 'longevity,' 'fiberglass-reinforced posts' or 'metallic posts.' The second search strategy involved analyzing the references of articles identified by the first search. Both studies were carried out with stringent inclusion and exclusion criteria. Results: No statistically significant and clinically relevant differences in longevity were observed between metallic and fiberglass posts. Conclusion: The clinical success and durability of the restorative procedure using intraradicular posts primarily depend on the remaining amount around the post (ferrule), the type and position of the tooth in the arch (impacting the masticatory forces exerted on the restored tooth), and the correct application of the cementation technique. It is noteworthy that fiberglass posts offer substantial advantages by presenting a modulus of elasticity similar to dental structure, ensuring a more homogeneous distribution of masticatory forces and reducing the risk of fractures. These findings have practical implications for material selection in restorative procedures involving intraradicular posts.(AU)


Objetivo: Esta revisão sistemática visa comparar a longevidade clínica de pinos intrarradiculares metálicos e de fibra de vidro em dentes com coroas severamente comprometidas, através de estudos clínicos randomizados e relatos de casos, publicados nos últimos onze anos. Material e Métodos: A pesquisa foi conduzida nas bases de dados PubMed, Medline, Lilacs e BBO, utilizando a primeira estratégia de busca com os s 'pinos dentais' e 'longevidade' e 'pinos reforçados com fibra de vidro' ou 'pinos metálicos'. A segunda estratégia de busca consistiu na análise das referências dos artigos identificados pela primeira estratégia. Ambos os estudos foram delineados com critérios rigorosos de inclusão e exclusão. Resultados: Não se constataram diferenças estatisticamente significativas e clinicamente relevantes na longevidade entre pinos metálicos e de fibra de vidro. Conclusão: O êxito clínico e a durabilidade do procedimento restaurador empregando pinos intrarradiculares dependem primordialmente da quantidade de remanescente ao redor do pino (férula), do tipo e posição do dente na arcada (o que impacta nas forças mastigatórias exercidas sobre o dente restaurado) e da aplicação correta da técnica de cimentação.Destaca-se que o pino de fibra de vidro oferece vantagens substanciais ao apresentar módulo de elasticidade similar à estrutura dentária, assegurando uma distribuição mais homogênea das forças mastigatórias e reduzindo o risco de fraturas (AU)


Subject(s)
Dental Materials , Dental Pins
2.
Braz. dent. sci ; 26(4): 1-10, 2023. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1523860

ABSTRACT

Objective: The aim of this in vitro study w as t o analyze the influence of the titanium dioxide nanotubes i n a self-cure mode polymerization of a dual resin luting agent through push out bond strength and radiopacity tests. Material and Methods: After mixed with a commercial du al self-adhesive resin cement, three concentrations o f tit anium dioxide nanotubes (0.3, 0.6, and 0.9% by weight) we re analyzed in self-curing mode. T he bond strength to bovine root dentin and fi berglass posts was assessed with the push out bond str ength t est and was evaluated in three thirds (cervical, middle and apical) (n=10), followed by failure mode analysis (SEM), and the ISO standard 9917-2 was followed for radiopacity test (n=10). Data were statistically analyzed by one-way ANOVA test, followed by Tukey's test (α=0.05). Results: Reinforced self-adhesive resin cement with 0.6% titanium dioxide nanotubes showed significant difference compared to the control gr oup for push out test (p=0.00158). The modified groups did not s how significant difference among thirds (p=0.782). Radiopacity sh owed higher value for group w ith 0.9% titanium dioxide nanotubes in comparison w ith control group (p<0.001). Conclusion: The addition of titanium dioxide nanotubes to a self-adhesive resin cement increased the bond strength to dentin and radiopacity values in the self-cure polymerization mode (AU)


Objetivo: O objetivo deste estudo in vitro foi analisar a influência de nanotubos de dióxido de titânio na polimerização química de um agente cimentante resinoso dual através de testes de resistência à união e radiopacidade. Material e Métodos: Após misturado com um cimento resinoso auto-adesivo comercial, três concentrações de nanotubos de dióxido de titânio (0,3, 0,6 e 0,9% em peso) foram analisadas. A resistência da união para a dentina da raiz bovina e os pinos de fibra de vidro foi avaliada pelo teste de push-out e avaliada em três terços (cervical, médio e apical) (n = 10), seguido pelo análise de modo de falha (MEV) e a norma ISO 9917-2 foi seguido para teste de radiopacidade (n = 10). Os dados foram analisados estatisticamente pelo teste ANOVA um fator seguido do teste de Tukey (α = 0,05). Resultados: O cimento resinoso auto-adesivo reforçado com nanotubos de dióxido de titânio a 0,6% mostrou diferença significativa em comparação com o grupo controle para teste de push-out (p=0,00158). Os grupos modificados não mostraram diferença significativa entre os terços (p=0,782). A radiopacidade mostrou maior valor para o grupo com nanotubos de dióxido de titânio 0,9% em comparação com o grupo controle (p<0,001). Conclusão: A adição de nanotubos de dióxido de titânio a um cimento resinoso auto-adesivo aumentou a os valores de resistência de união à dentina e radiopacidade no modo de polimerização química do agente cimentante (AU)


Subject(s)
Titanium , Dental Cements , Dental Pins , Nanotubes
3.
Braz. j. oral sci ; 21: e223759, jan.-dez. 2022. ilus
Article in English | LILACS, BBO | ID: biblio-1355009

ABSTRACT

Aim: To evaluate the fracture resistance of roots restored with CAD/CAM-fabricated posts, receiving or not intracanal laser treatment, compared with glass fiber posts under mechanical cycling. Methods: Twenty-seven endodontically treated, single-rooted teeth were divided into 3 groups: group 1 (control), prefabricated glass fiber posts relined with resin composite; group 2, CAD/CAM-fabricated intraradicular posts using Resin Nano Ceramic (RNC) blocks; and group 3, CAD/CAM-fabricated intraradicular posts using RNC blocks in canals irradiated with a 940-nm diode laser (100 mJ, 300-um optic fiber, coronal-apical and apical-coronal helical movements, speed of 2 mm/second, 4 times each canal). After cementation of the coping, cyclic loading was applied at an angle of 135° to the long axis of the root, with a pulse load of 130 N, frequency of 2.2 Hz, and 150,000 pulses on the crown at a point located 2 mm below the incisal edge on the lingual aspect of the specimen. Every 50,000 cycles, the specimens were evaluated for root fracture occurring below or above the simulated bone crest. Results were analyzed by one-way ANOVA followed by Tukey's test (p<0.05). Results: Group 1 was the least resistant, while groups 2 and 3 were the most resistant. Group 1 differed significantly from groups 2 and 3 (p<0.01), but there was no difference between groups 2 and 3 (p<0.01). Conclusion: Treatment of the intracanal surface with diode laser had no influence on fracture resistance of roots restored with CAD/CAM-fabricated posts, but a longer cycling time is required to evaluate the real benefits of diode laser irradiation


Subject(s)
Humans , Tooth Fractures/rehabilitation , Tooth Root/injuries , Dental Pins , Dentistry , Lasers, Semiconductor/therapeutic use
4.
Rev. Cient. CRO-RJ (Online) ; 7(1): 76-81, Jan-Apr 2022.
Article in English | LILACS, BBO | ID: biblio-1382199

ABSTRACT

Objective: To describe a clinical case that called for an anatomical post to be made to support and retain an indirect restoration in the anterior tooth. Case report: A 72-year-old female patient came to the office complaining that the crown of tooth 22 had come loose. A clinical and radiographic examination of element 22 was performed, and showed a very broad root canal, total displacement of the cast metal crown-core set, and satisfactory endodontic treatment. The restorative planning for this patient included the making of an anatomical post from Exacto # 2 fiberglass post (Angelus, Brazil), and refilling it with Bulk One composite resin (3M, USA), using self-adhesive resin cement U200 (3M, USA). The reconstruction of the coronary portion of the post was also performed with the same composite resin (Bulk One 3M, USA). The preparation for full crown and temporary restoration was performed in the same session, using self-curing acrylic resin. The all-ceramic crown was molded and cemented in subsequent sessions. Conclusion: The use of anatomical posts with composite resin represents a technically viable alternative for rehabilitating endodontically treated teeth with wide root canals, in cases where conventional prefabricated fiber posts cannot be adapted easily. The advantages that stand out are that these posts can be applied easily, at low cost, and in a single session.


Objetivo: Descrever um caso clínico de confecção do pino anatômico para suporte e retenção de restauração indireta em dente anterior. Relato do Caso: Paciente feminina, 72 anos, compareceu ao consultório queixando-se que a coroa do dente 22 havia "soltado". Realizou-se exame clínico e radiográfico do elemento 22, que apresentou conduto radicular bastante amplo, deslocamento total do conjunto núcleo/coroa e tratamento endodôntico satisfatório. O planejamento restaurador para essa paciente incluiu a confecção de pino anatômico, com pino de fibra de vidro Exato #2(Angelus, Brasil) reembasado com resina composta Bulk One (3M, EUA), utilizando o cimento resinoso autoadesivo U200 (3M, EUA). Foi realizada a reconstrução da porção coronária do pino também com resina composta do tipo Bulk. Realizou-se, na mesma sessão de atendimento, o preparo para coroa total e restauração provisória utilizando dente de estoque e resinaacrílica autopolimerizável. Em sessões seguintes foi realizada a moldagem e cimentação da coroa total em cerâmica pura. Conclusão: A utilização de pinos anatômicos com resina composta representa uma alternativa tecnicamente viável, de fácil aplicabilidade, com baixo custo e em única sessão, para reabilitação de dentes tratados endodonticamente com conduto radicular onde os pinos em fibra pré-fabricados convencionais não apresentam boa adaptação.


Subject(s)
Humans , Female , Aged , Post and Core Technique , Dental Pins , Dental Restoration, Permanent/instrumentation , Composite Resins , Dental Materials , Glass
5.
Rev. Odontol. Araçatuba (Impr.) ; 43(1): 45-50, jan.-abr. 2022. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1361713

ABSTRACT

O objetivo deste relato de caso foi descrever em detalhes a técnica de transfixação de pino de fibra de vidro no sentido horizontal e restauração de resina composta em um dente molar tratado endodonticamete. Paciente, sexo feminino, 51 anos de idade, buscou o Centro Universitário da Serra Gaúcha (FSG ­ Caxias do Sul ­ Rio Grande do Sul) com a necessidade de realizar tratamento endodôntico do elemento molar número 26. Após a avaliação inicial, foi realizada a endodontia. O elemento havia pouca sustentação das paredes vestibular e palatina, então foi proposto a colocação de pino intrarradicular seguido de coroa, entretanto, por questões financeiras a paciente não aceitou. Logo, foi proposto a técnica de transfixação horizontal de pino de fibra de vidro associado a uma restauração de resina composta de forma direta. O procedimento foi realizado em sessão única e foi utilizado um pino de fibra de vidro número 1 disposto transversalmente entre as paredes mesiopalatina e distovestibular. A restauração foi realizada com resina composta Filtek Z350, devolvendo estética e função ao elemento dentário. Pode-se concluir que a técnica de transfixação horizontal de pino de fibra de vidro associado à resina composta é uma alternativa restauradora que possibilita maior resistência aos dentes tratados endodonticamente, apresenta resultados funcionais e estéticos satisfatórios, além de possibilitar uma maior sobrevida aos mesmos(AU)


The purpose of this case report was to describe in detail the technique of horizontal transfixion of a fiberglass post into an endodontically treated tooth. Female patient, 51 years old, sought the University Center of Serra Gaúcha (FSG - Caxias do Sul ­ Rio Grande do Sul) with the need to perform the endodontic treatment of molar element number 26. After the initial evaluation, endodontics was performed. The element had little support for the buccal and palatal walls, so an intraradicular postplacement followed by a crown was proposed, for financial reasons the patient did not accept it. Therefore, the technique of horizontal transfixion of a fiberglass pin was proposed, associated with a restoration of direct composite resin. The procedure was performed in a single session and a number 1 fiberglass post was fixed crosswise between the mesiopalatal and distobuccal walls. The restoration was carried out with composite resin Filtek Z350, restoring aesthetics and function. It can be concluded that the horizontal transfixion of a fiberglass post associated with composite resin technique is a restorative alternative that allows greater resistance to endodontically treated teeth, provides satisfactory esthetics and better survival rates(AU)


Subject(s)
Humans , Female , Middle Aged , Composite Resins , Tooth, Nonvital , Dental Pins , Molar , Root Canal Filling Materials , Root Canal Therapy , Dental Restoration, Permanent , Flexural Strength
6.
Belo Horizonte; s.n; 2022. 97 p. ilus.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1428871

ABSTRACT

A cimentação de pinos de fibra de vidro à dentina intrarradicular, principalmente no terço apical, continua sendo um desafio na odontologia. O objetivo desse estudo foi avaliar a influência do controle de umidade com etanol na resistência de união de pinos de fibra de vidro em diferentes terços de dentina intrarradicular, 24 horas e 6 meses após o processo de cimentação adesiva. Sessenta e quatro incisivos bovinos extraídos foram submetidos ao tratamento endodôntico e divididos em dois grupos, de acordo com o tipo de controle de umidade (técnica convencional e alcoólica). Cada grupo foi dividido em 4 subgrupos (n=8) de acordo com a cimentação: RXU: Single bond Universal + RelyX Ultimate; PNV: primer de dentes Panavia V5 + Panavia V5; U200: RelyX U200; SET: Set PP. A resistência de união do pushout foi medida em diferentes áreas da interface entre o pino e a superfície radicular, 24 horas e 6 meses após o procedimento de união. Os dados foram submetidos ao teste de Bonferroni (α = 0,05). Os menores valores de resistência de união foram encontrados para o grupo SET, com diferença estatisticamente significante entre os demais grupos para os terços cervical e médio. Os maiores valores de resistência de união foram encontrados para o grupo PNV com diferença estatisticamente significante para os demais grupos nos terços médio e apical em 24 horas. Avaliando os diferentes terços, em geral, os maiores valores de resistência de união foram encontrados para o terço cervical. O grupo PNV apresentou maiores valores de resistência de união para os terços cervical e médio, sem diferença estatisticamente significante entre eles. Quanto ao tipo de controle de umidade, pode-se observar que não há diferença estatisticamente significativa para o grupo PNV às 24 horas, U200 e SET aos 6 meses. Na comparação entre os tempos (24 horas e 6 meses), em geral, os valores de resistência de união diminuíram após o armazenamento. Diferenças significativas com menores valores foram observadas após o tempo de seis meses nos valores de envelhecimento para a resistência de união. Por meio de um microscópio óptico e um aparelho de microscopia eletrônica de varredura o padrão de fratura na interface adesiva foi caracterizado.


Cementation of fiberglass posts to intraradical dentin, especially in the apical third, remains a challenge in dentistry. The study was to evaluate the influence of moisture control with ethanol on the bond strength of fiberglass posts in different thirds of intraradicular dentin, 24 hours and 6 months after the adhesive cementation process. Sixty-four extracted bovine incisors were endodontically protected and divided into two groups, according to the type of moisture control (conventional and alcoholic technique). Each group was divided into 4 subgroups (n=8) according to cementation: RXU: Single bond Universal + RelyX Ultimate; PNV: Panavia V5 tooth primer + Panavia V5; U200: RelyX U200; SET: Set PP. The pushout bond strength was measured in different areas of the interface between the post and the root surface, 24 hours and 6 months after the bonding procedure. The data were confirmed by the Bonferroni test (α = 0.05). The lowest bond strength values were found for the SET group, with a statistically significant difference between the other groups for the cervical and middle thirds. The highest bond strength values were found for the PNV group, with a statistically significant difference for the other groups in the middle and apical thirds at 24 hours. Evaluating the different thirds, in general, the highest bond strength values were found for the cervical third. The PNV group showed higher bond strength values for the cervical and middle thirds, with no statistically significant difference between them. As for the type of humidity control, it can be observed that there is no statistically significant difference for the PNV group at 24 hours, U200 and SET at 6 months. In the comparison between times (24 hours and 6 months), in general, the bond strength values decreased after storage. Minor elevation differences with values were observed after the six-month time in the ageing values for bond strength. Using an optical microscope and a scanning electron microscopy device, the fracture pattern at the adhesive interface was characterized.


Subject(s)
Dentin-Bonding Agents , Dental Cements , Dental Pins , Dentin
7.
Braz. dent. sci ; 25(4): 1-14, 2022. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1395942

ABSTRACT

The current review aimed to compare the mechanical properties and clinical behavior of fiberglass and cast metal posts. It included in-vitro studies, finite element analysis, clinical studies, and systematic reviews that evaluated fiberglass and metal posts with reliable methodologies. The reports in the literature diverge on tooth failure modes and stress distributions in the root according to different posts. Investigations suggest that fiberglass posts are preferable because their elastic modulus is similar to dentin. Other studies mention that the flexibility of fiber posts may damage the interface. The fracture load values of different studies could not be compared. The presence of a ferrule seems beneficial. Cast metal posts provide higher characteristic strength to the set but with more unfavorable failures. Intraradicular posts with a lower elastic modulus produce more stress between the cement layer and dentin. In conclusion, fiberglass and cast metal posts can be used with a ferrule. Cast metal posts seem more appropriate for weakened teeth. The presence of a ferrule benefits the system. Weakened teeth tolerate higher loads when restored with cast metal posts, but when these posts fail, the only solution is tooth extraction. Clinical follow-ups cannot yet detect differences between the survival rates of intraradicular fiberglass and cast metal posts (AU)


O objetivo da presente revisão foi comparar as propriedades mecânicas e o comportamento clínico de pinos de fibra de vidro e núcleos metálicos fundidos. Estudos laboratoriais, analise por elementos finitos, estudos clínicos e revisões sistemáticas que avaliaram pinos de fibra de vidro e metálicos, com metodologia confiável foram selecionados. A literatura mostra-se bastante controversa sobre os modos de falha do dente e a distribuição de tensões na raiz de acordo com diferentes tipos de pinos. Algumas investigações sugerem que pinos de fibra de vidro são preferíveis porque seu módulo de elasticidade é semelhante ao da dentina, enquanto outras mencionam que a flexibilidade do pino de fibra pode ser prejudicial à interface adesiva. Os valores de carga de fratura em diferentes estudos não podem ser comparados. A presença de férula é benéfica. O núcleo metálico fundido resulta em maior resistência característica do conjunto, mas falhas mais desfavoráveis. Também, pinos com menor módulo geram mais tensão entre a camada de cimento e a dentina. Em conclusão, verificou-se que tanto pino de fibra de vidro como núcleo metálico fundido podem ser utilizados quando a férula está presente. Os núcleos metálicos fundidos parecem ser mais indicados para dentes fragilizados. É evidente que a presença de férula é benéfica para o sistema. Dentes fragilizados toleram cargas maiores quando restaurados com núcleos metálicos fundidos; porém, quando falham, a única solução é a extração do dente. Os acompanhamentos clínicos ainda não são capazes de detectar diferença entre as taxas de sobrevivência dos pinos de fibra de vidro e núcleos metálicos (AU)


Subject(s)
Prosthodontics , Dental Prosthesis , Finite Element Analysis , Dental Pins
8.
RFO UPF ; 26(2): 323-333, 20210808. tab
Article in English | LILACS, BBO | ID: biblio-1452537

ABSTRACT

Objetivo: O objetivo deste estudo foi responder qual é a melhor técnica para remoção de pinos de fibra de vidro e pinos metálicos fundidos considerando tempo, preservação da estrutura dentária e custos. Métodos: Foi realizado um estudo in vitro, randomizado e cego. Sessenta dentes tratados endodonticamente foram randomizados em dois grupos de acordo com o tipo de pino. Uma segunda randomização foi realizada para cada tipo de técnica de remoção (ultrassom, broca ou combinada; n=10). One-way ANOVA foi usado para comparar o tempo de remoção do pino, teste t pareado comparou a quantidade de estrutura dentária removida e Kruskal Wallis seguido pelo teste post hoc de Mann-Whitney foram usados para análise de custo (P = 0,05). Resultados: Não houve diferença no tempo de remoção do pino considerando o tipo ou técnica do pino (P=0,630). A perda média de estrutura dentária na região cervical foi superior a 30% quando apenas uma ponta diamantada foi usada para remover pino de fibra de vidro (P<0,00001) e pino metálico fundido (P=0,008). Conclusão: De acordo com os resultados deste estudo, podemos concluir que a seleção da técnica de remoção dependerá da habilidade do operador, e sempre ocorrerá alguma perda de estrutura dentária, embora seja esperada uma perda maior quando apenas pontas diamantadas são usadas para este fim.(AU)


Objective: The aim of this study was to answer which is the best technique to removing glass fiber post and cast metal post considering time, preservation of tooth structure, and costs. Methods: An in vitro, randomized, blinded study was conducted. Sixty endodontically treated teeth were randomized into two groups according to post type. A second randomization was performed for each type of removal technique (ultrasound, drill, or combined; n=10). One-way ANOVA was used to compare the time to post removal, paired t-test compared the amount of tooth structure removed and Kruskal Wallis followed by post hoc Mann-Whitney test were used for cost analysis (P=0.05). Results: There was no difference in post removal time considering post type or technique (P=0.630). The average loss of tooth structure in the cervical region was greater than 30% when only a diamond bur was used to remove fiber glass post (P<0.00001) and cast metal post (P=0.008). Conclusion: According to the results of this study, we can conclude that the selection of the removal technique will depend on the skill of the operator, and some loss of tooth structure will always occur, although greater loss is expected when only diamond burs are used for this purpose.(AU)


Subject(s)
Humans , Post and Core Technique/economics , Device Removal/economics , Dental Pins/economics , Reference Values , Time Factors , Random Allocation , Analysis of Variance , Statistics, Nonparametric , Costs and Cost Analysis , Device Removal/methods
9.
Rev. Fac. Odontol. Porto Alegre (Online) ; 62(1): 44-55, jan.-jun. 2021.
Article in Portuguese | LILACS, BBO | ID: biblio-1443417

ABSTRACT

Introdução: O objetivo deste trabalho foi avaliar a influência de diferentes métodos de tratamento de superfície em pinos de fibra de vidro com relação a sua força de união com a resina composta e avaliar os tipos de falhas ocorridas. Materiais e Métodos: Foram utilizados 36 pinos da WhitepostDC (grupo GF) e Exacto Cônicos (grupo GA), divididos em: Grupos controle GF-1 e GA-1 ­ aplicação de silano de acordo com as especificações do fabricante; Grupos GF-2 e GA-2 ­ condicionamento com peróxido de hidrogênio a 10% e silanização; Grupos GF-3 e GA-3 ­ Jateamento com óxido de alumínio por 10 segundos e silanização. A adição da resina composta foi realizada em incrementos de 2 mm, com fotopolimerização de cada incremento por 40 segundos, até o preenchimento de toda extensão da matriz. Então, o conjunto pino e resina composta foi seccionado em três porções (cervical, médio e apical) (n = 18). As amostras foram submetidas à análise de resistência de união através do teste Push-Out em uma Máquina de Ensaio Universal (EMIC), e os tipos de falhas foram avaliados com aumento 30 × com um microscópio óptico. Os dados foram submetidos à análise de variância, ao teste de Tukey e ao teste de qui-quadrado com significância de 5%. Resultados: Nos grupos GA, o tratamento com silano (23,10 MPa) resultou em resistência de união estatisticamente maior que os tratamentos com peróxido (17,19 MPa) e com jateamento (16,28 MPa). No tratamento com peróxido, a resistência de união foi estatisticamente maior no terço médio (21,16 MPa) que no terço apical (12,55 MPa). A falha do tipo mista teve a maior prevalência (57,01%). Conclusão: O tratamento com silano apresentou maior resistência de união, com diferença estatística dos demais grupos na marca Angelus


Introduction: The aim of this study was to evaluate the influence of different surface treatment methods on glass-fiber posts relative to their bond strength with the composite resin and to evaluate the types of failures that occurred. Materials and Methods: Thirty-six posts from WhitepostDC (FG group) and Exacto Conics (AG group) were used, divided into: Control FG-1 and AG-1 groups ­ application of silane, according to manufacturers' specifications; FG-2 and AG-2 groups ­ conditioning with 10% hydrogen peroxide and silanization; FG-3 and AG-3 groups ­ aluminum oxide blasting for 10 seconds and silanization. The composite resin was added in 2-mm increments, each increment was photopolymerized for 40 seconds, until the entire length of the matrix was filled. Then, the assembly (fiber post and composite resin) was sectioned into three portions (cervical, middle and apical) (n = 18). Samples were submitted to the bond strength analysis by a push-out test in a Universal Testing Machine and the failure types were evaluated with a 30 × magnification with an optical microscope. Data were submitted to the analysis of variance, the Tukey test, and the chi-square test with a 5% significance level. Results: For AG groups, the treatment with silane (23.10 MPa) resulted in statistically greater bond strength than the treatments with peroxide (17.19 MPa) and blasting (16.28 MPa). It was found that the bond strength was statistically higher in the middle third (21.16 MPa) than in the apical third (12.55 MPa) for the peroxide treatment. The mixed-type failure had the highest prevalence (57.01%).


Subject(s)
Materials Testing , Composite Resins , Dental Pins
10.
Rev. Salusvita (Online) ; 40(3): 83-102, 2021.
Article in Portuguese | LILACS | ID: biblio-1524730

ABSTRACT

Introdução: A dentística a cada dia demonstra grandes avanços nas técnicas e materiais, sendo eles aplicados de forma a preservar a estrutura dentária. Neste sentido, os pinos de fibra de vidro (PFVs) se destacam como uma alternativa de pinos intrarradiculares para a reabilitação de dentes endodonticamente tratados com perdas estruturais superiores a 50%. Objetivo: Realizar uma revisão de literatura sobre os pinos de fibra de vidro enfatizando seus aspectos gerais, propriedades e considerações biomecânicas. Materiais e métodos: Realizou-se uma revisão bibliográfica de estudos publicados nos últimos 21 anos (2000-2021), por meio de busca nas bases de dados: PubMED/MEDLINE, SciELO (Scientific Eletronic Library) e Google Acadêmico. Para a pesquisa, foram utilizados os seguintes descritores: Dente não Vital (Tooth, Nonvital), Pinos Dentários (Dental Pins) e Técnica para Retentor Intrarradicular (Post and Core Technique). Após criteriosa filtragem, foram selecionados 30 trabalhos para inclusão no estudo, além de 10 livros considerados relevan-tes para esta revisão. Resultado:Os PFVs demonstram excelentes propriedades estéticas, facilidade de execução da técnica e baixo custo, biocompatibilidade com tecidos dentais e perirradiculares, além de características biomecânicas vantajosas, o que resulta na trans-missão de menos tensão para a estrutura dentária, diminuindo a probabilidade de fratu-ras. Conclusão: As inúmeras vantagens e o excelente comportamento biomecânico desses pinos explicam seu destaque frente aos demais retentores intrarradiculares, sendo esses, quando bem indicados, a primeira opção para a reabilitação de dentes tratados endodonti-camente com extensas perdas coronárias.


Introduction: Every day, dentistry demonstrates great advances in techniques and materials applied to preserve the tooth structure. In this sense, fiberglass posts (FGPs) attract attention as an alternative to intraradicular posts for the rehabilitation of endodontically treated teeth with structural losses greater than 50%. Objective: Review the literature on aesthetic fiberglass posts, emphasizing their general aspects, properties, and biomechanical considerations. Material and Methods: A literature review of studies published in the last 21 years (2000-2021) through a search on the databases: PubMED / Medline, Scielo (Scientific Electronic Library), and Google Academic. The following descriptors were used: Tooth, Nonvital, Dental Pins, and Post and Core Technique. After careful filtering, 30 articles were selected for inclusion in the study, in addition to 10 books considered relevant to this review. Results: The FGPs demonstrate excellent aesthetic properties, eas-iness of execution and low cost, biocompatibility with dental and periradicular tissues, in addition to advantageous biomechanical characteristics, which result in the transmission of less stress to the tooth structure, reducing the probability of fractures. Conclusion: The numerous advantages and excellent biomechanical behavior of these pins explain their prominence concerning other intraradicular retainers, which, when properly indicated, are the first option for the rehabilitation of endodontically treated teeth with extensive coronary loss. Keywords: Tooth, Nonvital. Dental Pins. Post and Core Technique.


Subject(s)
Post and Core Technique , Tooth, Nonvital , Dental Pins
11.
Rev. Salusvita (Online) ; 40(4): 116-142, 2021.
Article in Portuguese | LILACS | ID: biblio-1525470

ABSTRACT

Introdução: Os pinos de fibra de vidro (PFVs) apresentam-se como uma alternativa prática e econômica capaz de reabilitar dentes endodonticamente tratados com perdas estruturais superiores a 50%. Objetivo: Realizar uma revisão de literatura sobre o protocolo clínico acerca da utilização dos PFVs, bem como explanar as diferentes técnicas que po-dem ser utilizadas para implementá-los. Materiais e métodos: Realizou-se uma revisão bibliográfica de estudos publicados entre 2000 e 2021 por meio da busca nas bases de dados: PubMED/Medline, Scielo (Scientific Eletronic Library) e Google Acadêmico. Para a pesquisa, foram utilizados os seguintes descritores: Dente não Vital (Non-vital Tooth), Pinos Dentários (Dental Pins) e Técnica para Retentor Intrarradicular (Post and Core Technique). Após criteriosa filtragem, foram selecionados 24 trabalhos para inclusão no estudo, além de 10 livros considerados relevantes para esta revisão. Resultados: Durante o diagnóstico e planejamento, é necessário avaliar determinados fatores para que se obtenha sucesso clínico, como: quantidade de estrutura dentária remanescente, posição dentária e forças oclusais recebidas e necessidades restauradoras e estéticas exigidas pelo caso e pelo paciente. Diante das particularidades de cada caso, o clínico deve selecionar entre as técnicas a mais ideal: Técnica do PFV direto/ técnica convencional; Técnica do pino de fibra de vidro anatômico; ouTécnica direta com PFV associado a pinos acessórios. Conclusão: A técnica do PFV apresenta passos clínicos simplificados e sua correta realização garante sucesso no tratamento. Diante de situações em que o PFV não apresenta correta adaptação, o clínico deve abrir mão da utilização da técnica convencional e utilizar as técnicas de personalização do PFV.


Introduction: Fiberglass posts (FPs) are presented as a practical and economical alternative capable of rehabilitating endodontically treated teeth with 50% structural losses greater than 50%. Objective: To review the literature on the clinical protocol for the use of FPs, as well as explain the different techniques that can be used. Materials and methods: A literature review of studies published between 2000 and 2021 was carried out through a search on the Scielo (Scientific Electronic Library) and Google Scholar databases. The following descriptors were used for the research: Non-Vital Tooth, Dental Pins, and Technique for Intraradicular Retainer (Post and Core Technique). After careful screening, we selected 24 papers and 10 books, considered relevant for this review. Results: During planning, it is necessary to determine specific factors for clinical success, such as the amount of remaining tooth structure, the tooth position and the occlusal forces received, and restorative and esthetic needs required by the case and the patient. Given each case's particularities, the clinician must select among the most ideal techniques: the direct FP technique/convention-al technique; the Anatomical fiberglass post technique, and the direct technique with FP associated with accessory posts. Conclusion: The FP technique has simplified clinical steps and its correct performance is successful in the treatment. Faced with situations in which the FP does not present adequate adaptation, the clinician must not use the conventional technique, using techniques for personalizing the FP.


Subject(s)
Tooth, Nonvital/therapy , Post and Core Technique , Dental Pins
12.
São José dos Campos; s.n; 2021. 73 p. ilus, graf, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1361284

ABSTRACT

Os fotopolimerizadores vêm sendo utilizados como dispositivos fundamentais na Odontologia para confecção de restaurações. No entanto, a etapa de fotopolimerização da resina composta inadequada pode afetar a união entre o material restaurador e o substrato. No caso dos agentes cimentantes resinosos a dificuldade está na limitação do local de incidência da luz. Em cimentações de retentores intrarradiculares pré-fabricados, normalmente são utilizados os cimentos de ativação química ou dupla ativação, devido a limitações anatômicas. Portanto, o objetivo deste trabalho foi avaliar o efeito da emissão de luz com fibra óptica, na cimentação de retentor intrarradicular experimental capaz de fotoativar em toda a extensão do conduto radicular. No estudo foi confeccionado um protótipo de ponta acessória em fibra óptica para fonte transmissora de luz que acoplado a um aparelho fotoativador (Bluephase, Ivoclar, Brasil) transmite a luz pelo interior do conduto radicular. Desta forma foram confeccionados em parceria com a empresa Angelus, retentores experimentais vazados ao longo dos seus eixos em fibra de vidro parcialmente opacos. Para simulação do conduto radicular foram utilizadas 80 amostras de resina G10 seccionadas no tamanho de 10 mm de largura por 14 mm de altura (n=80). Cada amostra foi perfurada ao centro nas seguintes dimensões: diâmetro de 3,0 mm e 10 mm de altura. Para cimentação dos retentores intrarradiculares foram utilizados cimento resinoso fotoativado ou dual. A fotoativação foi realizada diretamente com a ponta do aparelho fotoativador ou utilizando o dispositivo experimental transmissor de luz. As amostras foram analisadas imediatamente ou após o envelhecimento térmico de 10.000 ciclos. Para análiseda resistência de união as amostras foram seccionadas em 3 partes, com 2 mm cada (coronal, média e apical) e submetidas aos testes de resistência de união por push out, seguido da análise estereomicroscópica e análise espectroscópica no infravermelho transformada por Fourier (FT-IR). O dispositivo experimental transmissor de luz foi avaliado quanto a sua irradiância, e esta obteve 50% da energia quando comparada com obtida diretamente da ponteira do fotoativador. Após testes mecânicos, os resultados encontrados foram submetidos aos testes estatísticos, Anova com 3 fatores (cimento x fotoativação x profundidade) e Anova 2 fatores (envelhecimento x cimento), seguida de teste Tukey com nível de significância de 5%. Nos resultados de resistência houve diferença estatística entre os tipos de cimentos, profundidade, fotoativação e interação entre oscimentos e a profundidade, sendo que os grupos cimentados com os cimentos fotoativados e com o dispositivo houve uma maior resistência de união na porção média e apical. Com relação ao grau de conversão houve uma maior conversão e a análise estereomicroscópica apresentou maior falha adesiva na porção apical, independente da realização do envelhecimento. Portanto, a utilização do dispositivo obteve resultados promissores e o retentor intrarradicular experimental contribuiu para aumentar a adesão entre o cimento e o substrato em sua porção mais apical.


Photopolymerizers have been used as a fundamental device in dentistry for making restorations. Nonetheless, the stage for the photopolymerization of the composite resin is critical and can affect the adhesion between the restorative material and the substrate. In the case of resin cementing agents, the difficulty lies in limiting the location of the incidence of light. In cementations of prefabricated intraradicular retainers, chemical activation or double activation cements are normally used, due to anatomical limitations. Therefore, the objective of this work was to evaluate the effect of light emission with optical fiber in the cementation of experimental intraradicular retainer capable of photoactivating in the entire length of the root canal. In the study, a prototype of fiber optic accessory tip for light transmitting source was made, which coupled to a photoactivator device (Bluephase, Ivoclar, Brazil) transmits the light inside the root canal. Thus, they were made in partnership with the company Angelus, experimental retainers cast along their axes in partially opaque fiberglass. For simulation of the root canal were used 80 samples of resin G10 sectioned in size 10mm wide by 14mm high (n=80). Each sample was drilled in the center in the following dimensions: diameter 3.0 mm and height 10 mm. For the cementation of the intraradicular seals, light-cured or dual resin cement was used. The photoactivation was performed directly with the tip of the photoactivator device or using the light transmitting experimental device. The samples were analyzed immediately or after thermal aging of 10,000 cycles. For bond strength analysis, the samples were sectioned into 3 parts, with 2 mm each (coronal, mean and apical) and submitted to the bond strength tests by push out, followed by the stereomicroscopic analysis and infrared spectroscopic analysis by Fourier (FTIR). The Light Transmitting Experimental Device was evaluated for its irradiance and obtained 50% of the energy when compared to that obtained directly from the tip of the photoactivator. After mechanical tests, the results found were submitted to the statistical tests Anova with 3 factors (cement x photoactivation x depth) and Anova 2 factors (aging x cement), followed by Tukey's test with a significance level of 5%. In resistance results, there was a statistical difference between the types of cements, depth, photoactivation and interaction between the cements and depth, and the groups cemented with the photoactivated cements and the device had a greater bond strength in middle and apical portion. Regarding the degree of conversion, there was a greater conversion and the stereomicroscopic analysis, it showed greater adhesive failure in the apical portion, regardless of the performance of aging. Therefore, the use of the device obtained promising results and the experimental intraradicular retainer contributed to increase the adhesion between the cement and the substrate in its most apical portion.


Subject(s)
Cementation , Dental Equipment , Dental Pins , Light-Curing of Dental Adhesives , Optical Fibers , Biocompatible Materials , Materials Testing , Analysis of Variance , Dental Cements
13.
Braz. dent. sci ; 24(2): 1-12, 2021. tab, ilus, graf
Article in English | LILACS, BBO | ID: biblio-1177776

ABSTRACT

Objective: The purpose of this study was to assess patient satisfaction, gross fracture and marginal adaptation of e.max press endocrowns versus e.max press crowns retained with Fiber reinforced composite post (FRCP) and core in upper anterior teeth. Material and methods: The present study included 24 patients seeking root canal treatment in anterior upper arch. The patients received root canal treatment (RCT) then they were randomly assigned into two groups (n=12). The first group received preparation for the IPS e.max crowns retained with FRCP and core and the second group received preparation for the IPS e.max endocrowns. Press technique was used for the fabrication of both restorations using IPS e.max press ingots. Marginal integrity and gross fracture were evaluated using USPHS criteria and a questionnaire was conducted to evaluate patient satisfaction. Data were analyzed using IBM SPSS Statistics for Windows, Version 23.0. Armonk, NY: IBM Corp. Results: There was no statistical significant difference regarding gross fracture of both groups after 12 months (p-value = 0.093, Effect size = 0.447), meanwhile; group 1 was statistically significantly higher than group 2 regarding marginal integrity (p-value = 0.037, Effect size = 0.513). Regarding patient satisfaction FRCP and core group showed statistical significant higher satisfaction than endocrown group (p-value = 0.047, Effect size = 0.447). Conclusion: E.max press endocrowns revealed successful performance similar to e.max press crowns retained with FRCP in terms of gross fracture, however better marginal adaptation and patient satisfaction was obtained with e.max press crowns retained with FRC post and core group. (AU)


Objetivo: O objetivo deste estudo foi avaliar a satisfação do paciente, grau de fratura grosseira e adaptação marginal de endocrowns e.max versus coroas de e.max retidas com pino de compósito reforçado com fibra (FRCP) e núcleo nos dentes anteriores superiores. Material e métodos: O presente estudo incluiu 24 pacientes que buscavam tratamento endodôntico na arcada superior anterior. Os pacientes receberam tratamento de canal radicular (RCT) e foram divididos aleatoriamente em dois grupos (n = 12). O primeiro grupo recebeu preparação para as coroas IPS e.max retidas com FRCP e núcleo e o segundo grupo recebeu preparos para as endocrowns IPS e.max. A técnica de prensagem foi usada para a fabricação de ambas as restaurações usando os lingotes de prensagem IPS e.max. A integridade marginal e a fratura macroscópica foram avaliadas usando os critérios da USPHS e um questionário foi realizado para avaliar a satisfação do paciente. Os dados foram analisados usando IBM SPSS Statistics for Windows, versão 23.0. Armonk, NY: IBM Corp. Resultados: Não houve diferença estatisticamente significativa em relação à fratura bruta de ambos os grupos após 12 meses (p-valor = 0,093, tamanho do efeito = 0,447), entretanto; o grupo 1 foi estatisticamente significativamente maior do que o grupo 2 em relação à integridade marginal (p-valor = 0,037, tamanho do efeito = 0,513). Em relação à satisfação do paciente, o FRCP e o grupo principal mostraram maior satisfação estatisticamente significativa do que o grupo endocrown (p-valor = 0,047, tamanho do efeito = 0,447). Conclusão: as endocrowns E.max press revelaram um desempenho bem-sucedido semelhante às coroas e.max press retidas com FRCP em termos de fratura bruta, no entanto, melhor adaptação marginal e satisfação do paciente foram obtidas com as coroas e.max press retidas com pilar FRC e núcleo de preenchimento (AU)


Subject(s)
Humans , Adult , Middle Aged , Root Canal Therapy , Dental Marginal Adaptation , Tooth, Nonvital , Dental Pins
14.
Dent. press endod ; 10(3): 36-42, Sept-Dec.2020. Ilus
Article in English | LILACS | ID: biblio-1344767

ABSTRACT

Introdução: Pinos intrarradiculares são recomendados para melhorar a retenção de coroas artificiais e distribuir forças intrabucais ao longo da raiz. Se o espaço criado pela remoção parcial da obturação não for preenchido adequadamente, pode ocorrer uma infiltração maciça de microrganismos da cavidade bucal. Objetivo: O objetivo do presente estudo foi avaliar a eficácia contra a infiltração bacteriana de uma barreira intracanal colocada diretamente sobre o remanescente da obturação do canal radicular, após o preparo de espaço para o pino. Métodos: Setenta e dois dentes humanos unirradiculares foram instrumentados, obturados e divididos aleatoriamente em três grupos experimentais e dois grupos controle. O grupo 1 não recebeu tratamento adicional após a obturação e o preparo do espaço, enquanto os Grupos 2 e 3 receberam uma barreira composta por material de selamento temporário com 1,0 e 2,0 mm de espessura, respectiva- mente. Uma cultura de Enterococcus faecalis foi inoculada nos espaços preparados para receber o pino intrarradicular, a cada três dias, por um período de 60 dias. A infiltração foi avaliada diariamente pela turbidade do meio de cultura. Resultados e Conclusão: Houve infiltração bacteriana nos três grupos experimentais, sendo significativamente maior e ocorrendo mais rapidamente no G1 (p<0,05), em comparação aos G2 e G3. Houve infiltração em todos os grupos controles positivos; porém, nenhuma infiltração foi observada nos grupos controles negativos. Não foi encontrada diferença significativa (p>0,05) entre o G2 e o G3, em relação à taxa e ao período de infiltração. Pode-se concluir que a barreira reduziu a incidência de infiltração e atrasou o tempo de ocorrência (AU).


Introduction: Intraradicular posts are recommended to improve the retention of artificial crowns and to distribute intraoral forces along the root. If the space created by partially removing the obturation is not adequately filled, it can lead to a massive infiltration of microorganisms from the oral cavity. Aim: The aim of this study was to assess the influence on bacterial infiltration of an intracanal barrier placed directly over the remaining root canal filling following post space preparation. Material and Methods: Seventy-two human single-rooted teeth were instrumented, filled, and then randomly divided into three experimental groups and two control groups. Group 1 received no additional treatment after filling and post space preparation, whereas Groups 2 and 3 received a barrier composed of temporary sealing material 1.0- and 2.0-mm thick, respectively. A culture of Enterococcus faecalis was inoculated into the spaces prepared to receive the intraradicular post, every three days over a 60-day period. Infiltration was evaluated daily by observing the turbidity of the culture medium. Results and Conclusion: Bacterial infiltration was found in all three experimental groups, but was significantly greater and occurred more quickly in G1 (p < 0.05), compared with G2 and G3. Infiltration was observed in all positive controls, whereas no infiltration was found in the negative controls. No significant difference (p > 0.05) was found between G2 and G3, regarding the rate and time frame of infiltration. It can be concluded that the barrier reduced the incidence of infiltration, and delayed the time of occurrence (AU).


Subject(s)
Humans , Root Canal Obturation , Enterococcus faecalis , Dental Pins , Efficacy , Crowns
15.
Rev. Odontol. Araçatuba (Impr.) ; 41(1): 47-52, jan.-abr. 2020. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1102380

ABSTRACT

O tratamento endodôntico frequentemente leva à perda de parte coronária de um elemento dentário, seja pelo enfraquecimento de sua estrutura, por lesões traumáticas ou por cárie. Desde que em condições favoráveis, esses dentes podem ser restaurados por meio de retenção adequada provida por meio de retentores intrarradiculares. Os pinos de quartzo utilizados como retentor intrarradicular surgiram com os avanços da odontologia adesiva, sendo uma opção relevante com inúmeras vantagens. A literatura odontológica aponta que a adaptação do pino às paredes do conduto radicular, somada a técnica de cimentação adesiva, são fatores essenciais para a longevidade do tratamento, sendo necessário em alguns casos sua personalização, para garantir melhor assentamento e promover prognóstico favorável. Objetivou-se neste artigo apresentar a técnica de preparo, personalização e cimentação do pino de quartzo na reconstrução de um dente tratado endodonticamente ilustrado por meio de caso clínico. Através de um protocolo ordenado e meticuloso da técnica de aplicação, foi possível alcançar o resultado desejado(AU)


Endodontic treatment often leads to loss of the coronary part of a tooth, either by weakening its structure, by traumatic lesions or by caries. Since under faborable conditions, these teetn can be restored by means of the biomechanical reinforcement promoted by the intraradicular retainers. The quartz posts have appeared with the advances of restorative dentistry, being a relevant option with numerous advantages. The dental literature indicates that the adaptation of the post to the root canal walls, together with the adhesive cementation technique, are essential factors for the longevity of the treatmet, being necessary in some cases its personalization, which guarantees its better settlement, avoiding the impression of undesirable forces to the tooth anf promoting better prognosis. The objective was to present the technique of preparation, personalization and cementation of the quartz post in the reconstruction of an endodontically treated tooth. Through an orderly and meticulous protocol of the application technique, it was possible to achieve the desired result(AU)


Subject(s)
Humans , Female , Adult , Quartz , Root Canal Filling Materials , Dental Cements , Dental Pins , Tooth, Nonvital
16.
Braz. dent. sci ; 23(3): 1-7, 2020. tab, ilus
Article in English | BBO, LILACS | ID: biblio-1116244

ABSTRACT

Objective: This study aimed to evaluate the biomechanical behaviour of endodontically treated teeth with direct veneer that received or not intra-radicular glass fiber post by finite elements analysis. Material and methods: Six models were designed, varying the presence or absence of glass fiber post and the thickness of direct veneer (0.5, 0.7 and 1 mm). Tridimensional models of maxillary central incisors were obtained with CAD software, Rhinoceros 4.0, and transferred to CAE software, ANSYS 17.2, which a 100N load was applied in a 45° on the lingual surface to simulate functional movements. Geometry contacts were bonded, and the structures were isotropic, linear, elastics, and homogeneous. After coherence and convergence analysis of mashes, the chosen fail criterion was the maximum principal stresses. Results: For cement, glass fiber post, the stress distribution was similar independently of glass fiber post presence or veneer thickness. Models with glass fiber post had better stress distribution and lower values of maximum stress for inner dentin and veneers. Veneers with 0.5 and 1 mm had higher stress concentration areas. Conclusions: It can be concluded that glass fiber post is favorable for restored teeth with direct veneers, and very thin or very thick preparations can damage the biomechanical behavior of restorations.(AU)


Objetivo: Este estudo teve como objetivo avaliar o comportamento biomecânico de dentes tratados endodonticamente com faceta direta que receberam ou não pinos de fibra de vidro intrarradicular através de análise de elementos finitos. Material e métodos: Foram desenhados seis modelos, variando a presença ou ausência do pino de fibra de vidro e a espessura da faceta direta (0,5, 0,7 e 1 mm). Modelos tridimensionais de incisivos centrais superiores foram obtidos com o software CAD, Rhinoceros 4.0, e transferidos para o software CAE, ANSYS 17.2, cuja carga de 100N foi aplicada a 45° na superfície lingual para simular movimentos funcionais. Os contatos geométricos foram colados e as estruturas eram isotrópicas, lineares, elásticas e homogêneas. Após análise de coerência e convergência de malhas, o critério de falha escolhido foi a tensão principal máxima. Resultados: Para cimento e pino de fibra de vidro, a distribuição de tensões foi semelhante independentemente da presença do pino de fibra de vidro ou da espessura da faceta. Os modelos com pinos de fibra de vidro apresentaram melhor distribuição de tensão e menores valores de tensão máxima para dentina interna e facetas. Facetas com 0,5 e 1mm apresentaram maiores áreas de concentração de estresse. Conclusões: Pode-se concluir que o pino de fibra de vidro é favorável para dentes restaurados com facetas diretas, e preparações muito finas ou muito espessas podem prejudicar o comportamento biomecânico das restaurações.(AU)


Subject(s)
Tooth, Nonvital , Finite Element Analysis , Dental Pins , Dental Veneers
17.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. ilus, tab
Article in English | LILACS, BBO | ID: biblio-1097768

ABSTRACT

Aim: To evaluate the influence of lengths and different luting agents on the bond strength of fiberglass posts' adhesion to dentin.Methods: Sixty single-root bovine teeth were endodontically treated and included in polyether and acrilyc resin to simulate a periodontal ligament. These were divided into 6 groups according to the post lengths (6, 10 or 14 mm) and luting agents (self-adhesive dual resin cement ­ U; or etch-and-rinse dual resin cement ­ A): U6, U10, U14, A6, A19, and A14. All fiberglass posts were cemented according to manufacturer instructions. After this, mechanical aging was performed (1.2x106 cycles; 4 Hz, 90 N). The push-out specimens were then conducted (2.0 ± 0.1 mm), with the test executed in a universal machine (10 kgf at 0.5 mm/min). Data obtained were submitted to the Kruskal-Wallis and Dunn's test. Results: No statistically significant difference was observed in bond strength between the groups due to the type of luting agent (p > 0.05). However, the isolated post-length factor showed significantly different results for the U groups (p < 0.05). The U10 group showed similar union values to U6 but statistically inferior to U14. Conclusion: bond strength of fiberglass posts of the same length as the dentin presented no differences according to the luting agent, but the post-length property influenced the bond strength when self-adhesive resin cement was used.


Objetivo: avaliar a influência dos agentes cimentantes e dos diferentes comprimentos de pinos na resistência de união de pinos de fibra de vidro a dentina. Métodos: Sessenta dentes bovinos uniradiculares tiveram a raiz endodonticamente tratada, e foram incluídos em poliéter e resina acrílica para simular o ligamento periodontal. Os espécimes foram divididos em seis grupos de acordo com o comprimento dos pinos (6, 10 ou 14mm) e dos agentes de cimentantes (cimento resinoso dual autoadesivo (RelyX U200, 3M ESPE) - U; ou cimento resinoso dual convencional (AllCem Core, FGM) - A: U6, U10, U14, A6, A19 e A14. Todos os pinos de fibra de vidro foram cimentados conforme as recomendações do fabricante. Após, o envelhecimento mecânico (1,2x106 ciclos; 4 Hz, 90 N) as amostras foram fatiadas para o teste de push-out (2,0 ± 0,1 mm) executado em uma máquina de ensaio universal (10 kgf a 0,5 mm/min). Os dados foram submetidos ao teste de Kruskal-Wallis e Dunn. Resultados: não houve diferença estatística na resistência de união entre os grupos devido ao tipo de agente cimentante (p > 0,05), mas houve para o comprimento dos pinos dos grupos U (p < 0,05). O grupo U10 apresentou valores de união semelhantes a U6, mas estatisticamente inferiores ao U14. Conclusão: a resistência de união dos pinos de fibra de vidro de um mesmo comprimento não apresentou diferenças mesmo quando cimentados com cimentos diferentes, mas o comprimento dos pinos isoladamente influenciou quando o cimento resinoso autoadesivo foi utilizado.


Subject(s)
Acrylic Resins , Materials Testing , Resin Cements , Dental Cements , Materials Science , Glass Ionomer Cements , Dental Pins
18.
Rev. odontol. UNESP (Online) ; 49: e20200001, 2020. tab
Article in English | LILACS, BBO | ID: biblio-1139423

ABSTRACT

Introduction: The resistance adhesive of a fiber post can be affected by several factors, such as the endodontic sealer and post-endodontic waiting time. Objective: The aim of this study was to evaluate the effect of different endodontic sealers and two different post-endodontic waiting times on the bond strength of fiber posts. Material and method: Seventy-two bovine teeth were endodontically treated and filled using three endodontic sealers: eugenol-based, epoxy resin-based, or mineral trioxide aggregate-based. The specimens were stored at 37°C for 24 hours or for 30 months. After the respective storage times, the root canals were prepared for luting fiber posts using RelyX U200. Push-out tests and analysis of failures were performed. The push-out data were analyzed by two-way analysis of variance to compare the effects of the endodontic sealer and with the t-test to compare the effects of post-endodontic waiting time. Result: The AH Plus sealer yielded the highest bond strength values at 30 months post-endodontics (11.26 Mpa) (p < 0.05), however no had difference with Endofill sealer at the same time. Endofill and MTA Fillapex sealers did not differ significantly in their effects, irrespective of the post-endodontic waiting time. Conclusion: In conclusion, the endodontic sealer used and post-endodontic waiting time affect the adhesive resistance of fiber posts. The adhesion increases significantly when the fiber post is cemented 30 months after the root canal filling, while the adhesion is reduced when cementing immediately after root canal treatment, in particular for eugenol-based endodontic sealers.


Introdução: A resistência de união de um pino de fibra pode ser afetada por vários fatores, como o cimento endodôntico e o tempo de espera pós-endodontia. Objetivo: Avaliar o efeito de diferentes cimentos endodônticos e dois tempos de espera pós-endodontia na resistência de união de pinos de fibra. Material e método: Setenta e dois dentes bovinos foram tratados endodonticamente e obturados usando três cimentos endodônticos: à base de eugenol, à base de resina epóxia ou à base de mineral trióxido agregado. Os espécimes foram armazenados a 37 ° C por 24 horas ou por 30 meses. Após, os canais radiculares foram preparados para cimentação dos pinos de fibra usando o RelyX U200. Foram realizados testes de push-out e análise de falhas. Os dados foram analisados por análise de variância bidirecional e com o teste t. Resultado: O cimento AH Plus obteve os maiores valores de resistência de união aos 30 meses pós-endodontia (11,26 Mpa) (p <0,05), no entanto, não houve diferença com o cimento Endofill no mesmo tempo. Os cimentos Endofill e MTA Fillapex não diferiram significativamente em seus efeitos, independentemente do tempo de espera pós-endodontia. Conclusão: O cimento endodôntico utilizado e o tempo de espera pós-endodontia afetam a resistência adesiva dos pinos de fibra. A adesão aumenta significativamente quando o pino de fibra é cimentado 30 meses após a obturação do canal radicular, enquanto a adesão é reduzida ao cimentar imediatamente após o tratamento do canal radicular, principalmente para cimentos endodônticos à base de eugenol.


Subject(s)
Cattle , Root Canal Obturation , Root Canal Therapy , Eugenol , Dental Cements , Dental Pins , Epoxy Resins , Analysis of Variance
19.
Article in English | LILACS, BBO | ID: biblio-1135547

ABSTRACT

Abstract Objective: To assess the tensile bond strength of prefabricated metal posts cemented with different luting agents. Material and Methods: Fifty single-rooted endodontically treated human teeth had their crowns cut, mounted into acrylic-resin blocks and then an 8mm depth post space were prepared. Prefabricated cylindrical metal posts were cemented using different luting agents: a zinc phosphate cement (SS White), a conventional glass ionomer cement (Vidrion C), two resin-modified glass ionomer cements (Vitremer and RelyX Luting 2) and a resin cement (RelyX ARC). Samples were stored in distilled water for seven days and then submitted to a tensile bond strength test until complete dislocation of the post. One-way analysis of variance and Tukey test for pairwise multiple comparisons were used to evaluate differences between luting agents. Results: Tensile bond strength was 563.88±203.41 N for zinc phosphate cement, 336.86 ± 137.64 N for Vidrion C, 515.24 ± 239.48 N for Vitremer, 828.47±433.99 N for RelyX Luting 2 and 1262.51 ± 356.29 for RelyX ARC. The Relyx ARC presented the highest tensile bond strength regard the luting agent tested (p< 0.05). Conclusion: RelyX ARC presented the higher tensile bond strength compared to the other luting agents evaluated.


Subject(s)
Tensile Strength , Resin Cements , Dental Cements , Glass Ionomer Cements , Zinc Phosphate Cement , Brazil/epidemiology , Analysis of Variance , Statistics, Nonparametric , Tooth, Nonvital/diagnosis , Dental Pins
20.
Dent. press endod ; 9(1): 26-30, jan.-mar. 2019. tab
Article in Portuguese | LILACS, BBO | ID: biblio-1000064

ABSTRACT

Objetivo: o objetivo do presente estudo foi comparar a resistência à fratura de quatro tipos de pinos intrarradiculares pré-fabricados: fibra de vidro, fibra de vidro customizado com resina composta, fibra de carbono e fibra de carbono customizado com resina, em dentes bovinos. Métodos: foram utilizados 60 dentes bovinos unirradiculares, que receberam tratamento endodôntico e foram divididos nos seguintes grupos: FV = pino de fibra de vidro; FVP = pino de fibra de vidro customizado; FC = pino de fibra de carbono; FCP = pino de fibra de carbono customizado; e Controle = restauração coronária com resina composta. Os dentes foram inseridos em blocos de resina acrílica, a 2 mm da junção amelocementária, simulando a interface dente-osso. Os espécimes foram submetidos ao teste de resistência à fratura em máquina de ensaio universal, sob uma carga de 0,5mm/min, até a fratura do corpo de prova. Os valores obtidos foram submetidos ao teste ANOVA, com pós-teste de Tukey. Foi realizada, também, uma análise dos padrões de fratura, por meio do teste Kruskal- -Wallis. Resultados: o grupo FCP mostrou os maiores valores de resistência à fratura, seguido pelos grupos FV, FVP e FC. O grupo controle mostrou menor resistência do que os demais, que receberam pinos intrarradiculares. Os pinos de FVP apresentaram o maior número de fraturas reparáveis, em contraste ao controle, no qual houve o maior número de fraturas desfavoráveis. Conclusão: o uso de pinos customizados reduziu a incidência de fraturas catastróficas. A ausência de pino intrarradicular ocasionou a maior incidência de fraturas irreparáveis. (AU)


Objective: The aim of this study was to compare the fracture resistance of four types of prefabricated intraradicular posts - glass fiber, glass fiber customized by composite resin, carbon fiber, and customized carbon fiber - on bovine teeth. Methods: Sixty bovine teeth were submitted to endodontic treatment and divided into the following groups: GF - glass fiber post; CGF - customized glass fiber post; CF - carbon fiber post; CCF - customized carbon fiber post; control - composite resin restoration. The teeth were embedded in acrylic resin blocks at 2 mm from the cement-enamel junction, simulating the teeth-bone interface. The specimens were submitted to a fracture resistance test in a universal test machine under a 0.5 mm/min load until the fracture of the specimen. The values obtained were submitted to ANOVA and Tukey tests. The analysis of the fracture patterns was performed by the Kruskal-Wallis test. Results: The CCF group presented the highest values of fracture resistance, followed by GF, CGF, and CF posts. The control group offered less resistance than the other groups that received intraradicular posts. The CGF presented the highest number of favorable fractures, in contrast to the control group, which presented the highest number of unfavorable fractures. Conclusion: The use of customized posts reduced the incidence of catastrophic fractures. The lack of intracanal posts led to a higher incidence of irreparable fractures (AU).


Subject(s)
Tooth Fractures , Dental Pins , Endodontics , Post and Core Technique , Dental Restoration, Permanent
SELECTION OF CITATIONS
SEARCH DETAIL